Latest Facial Equipment
Monopolar RF Beauty Equipment Skin Rejuvenation
Principle
of
Operation
|
The Monopolar RF beauty equipment is the high-tech beauty equipment, great safety.
The collagen is the main structure of skin. However, the collagen and elastin will reduce with aging,sun oxidation and air pollution. Skin will loose flexibility with age and collagen fibre will gradually lose elasticity and tensility.Sagging skin,or other visible signs of aging will appear.
The Monopolar RF equipment with the cooling system in surface layer, uses proprietary technology to deliver radiofrequency energy to the collagen tissue in the dermis layer. When deep collagen tissue is heated up to 45-60 it will naturally produce instant shrinking, stimulating new collagen fibres to take up interspace of the shrinking or lost collagen protein, and rebuilt skins soft tissue, resulting in tighter skin and younger looking skin, removes wrinkles, recovers skin elasticity and luster.
|
Special
Features
|
1. Collagen renewal: the RF energy can reach the deep layers of skin, stimulating the renewal of Collagen and Elastin. Resulting in tighter skin and renewed facial contours can be expected.
2. Treatment protocol: can be applied to any sagging and aging skin.
3. Instantaneous shrinking skin:when the temperature of collagen up to 45o- 60o
First time results to be seen - best results in series of 6-8 treatments.
4. Great safety: surface layer cooling makes the RF energy as its released speed can be controlled by client for greater safety during the treatment.
5. Comfortable: non-invasive radiofrequency technology, no blood, wound, or down time..
6. Long time effect last for 3-5 years.
|
Application
|
1. Face lifting
2. Skin lifting around eyes
3. Skin lifting on neck
4. Improve conditions of sagging skin
5. Forehead wrinkle removal
6. Breast lifting
7. Shape back contour
8. Shape belly contour
9. Shape buttocks and legs contour
10. Hand care, effective on removal of aging and wrinkled skin on Hands
|
Technical Parameter
|
RF Frequency
|
1 mHz
|
RF Energy
|
5-100J/cm^3
|
longevity
|
100,000 shots
|
Spectrum
|
HR 610-980nm SR530-980nm (Optional wave length range )
|
Spot Size
|
8×40mm2
|
Control way
|
LCD screen
|
 |
 |
Safety
|
online impedance testing
|
Net Weight
|
28kg
|
Specification
|
47cm×47cm×131cm (L×W×H)
|
Electrical Requirement
|
AC 220V±10% 50Hz 10A
AC 110V±10% 60Hz 10A
|
Certification
|
CE
|
Guarantee
|
1)Main part has one year warranty
2)Within 3 months, free to change the spare parts if come up quality problem.
3)Lifetime technology support
|
2.The function of RF:
1.Skin Rejuvenation
2.Remove Wrinkles,face lift,skin tighten
3.Body Shaping
3.Pictures of before and after treatment
Is it painfull?
As each person’s pain tolerance and threshold varies, it is difficult to quantify how painful or uncomfortable the treatment is. It also depends on the device used and the power settings for the treatment. Our machine let's the client choose the amount of heat that is well tolerated.
That is why the most frequently reported side effects of treatment with RF energy are swelling, redness, bumps and blisters on or around the treated area,will not occur with our treatment..
One of the most serious potential complications from RF energy treatment is a “depression”; this is attributed to the overheating of underlying tissue causing fat atrophy or excessive tightening, giving you a sunken appearance in the affected area. The occurrence of this also depends on the device used and appears to be only currently reported with the Thermacool™ system. (which is not our system)Generally, although further studies and more available data is needed, it is considered that there is a correlation between the occurrence of these depressions and the treatment being given at frequency levels above the manufacturer’s guidelines. It is therefore imperative that you make sure that your practitioner is adequately trained and certified to perform the RF treatment.
No special care is needed after treatment although your practitioner may suggest some of the following: cool water rinses or ice packs applied to the treatment area. Which willbe done in office with the cool wand.
As long as you are generally healthy and don’t have any skin diseases or infections in the area treated, there are few medical reasons why patients should not undergo this treatment.
People with sensory disturbance to the skin may not be considered good candidates as this could make the reporting of discomfort during the procedure unreliable, leading to potential harm.
Although there is no evidence that this treatment is harmful for pregnant women, you would generally be advised to wait until after you have given birth before embarking upon a course of treatment.
More importantly, people with electrical devices e.g., pacemakers, or metal implants e.g., artificial metal hip joints, heart valves or dental plates, cannot be treated because RF current flowing through the body may interfere with these devices or heat up metal implants, which could be dangerous.
Photon LED Light
|